machine description
4000 Watt5' x 10'Fanuc Resonator AF 4000iBAMNC-F ControlSingle Focus Lens TechnologyDual Pallets Chiller Cooler Orion RKE15002ADrive MMaximum Sheet Size 60” (Y) x 120” (X)Maximum Axis Travel 61.0” (Y) x 121” (X) x 3.94” (Z)Maximum Axis PositioningSpeed (X, Y)4,724 inches per minute per axis (6,681 inches per minute45o vector.)Maximum Speed Z-Axis 4,724 inches per minuteAcceleration X=1.5G Y=1.5G Z=3G XY Simultaneous= 2.12GPositioning Accuracy ±0.0004” OverallMaximum Material Weight 2,000 lbs.Assist Gas 4 ports with NC pressure ControlMachine Footprint 373” x 166”Machine Weight 11 Metric Tons (shuttle table is separate)Electrical Requirements 200V, 3 Phase, 60HzPageotors Fanuc Linear Drive motorsCNC CONTROLLERModel AMNC-FDisplay LCD Color Graphics DisplayControl Function X, Y, Z-Axis Simultaneous and Focus Lens B-axis, AdaptiveOptic and Laser Power control (CW, Gated Pulse, PierceRoutines etc.).Data Input Method Manual (MDI), Edit, RS-232 DNC, or 3 ½” PC compatibledisk, CD/DVD disk, USB, Ethernet, PCMCIAMinimum Command Unit 0.0001” (X, Y, Z)Minimum Travel Unit 0.0001” (X, Y, Z)Standard Memory 2 mbCompact Flash Drive 2 gbOperating Modes Automatic and ManualDisplay Modes Program Contents, Position Information, Program Check,Settings, Parameters, Beam Diameter Compensation,Assist Gas Status, Self Diagnostics, MaintenanceRemindersInterlock Displays Cooling Water Status, Gas Pressure Status, VacuumStatus, Turbo Blower Malfunction, Shutter Status, BeamPower, Resonator Discharge, Door Open.Electrical requirements 200V 3 Phase, 60HzLASER RESONATORModel Fanuc AF4000iBResonator Style Solid State RF Excited, Fast Axial Flow CO2.CW Output Power 4000WPeak Pulse Output Power 5000WPower Stability ± 2%Laser Wave Length 10.6?mLaser Power Mode Selection CW, Gated Pulse (CNC Controlled)Laser Beam Mode Output Low Order ModeBeam Diameter at Exit Less than 27mmBeam Divergence Less than 2mrad Full AnglePulse Frequency 5 – 2000HzPulse Duty 0 – 100%Laser Gas CO2: He: N2 (5%: 60%: 35% ratio by volume)Laser Gas Consumption 10 liters per hour (0.35 cubic feet per hour)Chiller Water Requirement ? 160 liters per min.Circular Polarizer YesInterlocks Electrical, Mechanical, Gases and ChillerElectrical Requirements 208 VAC, 3 Phase, 60HzElectrical Power Consumption 55kVA max.CHILLERModel Orion (Inverter Style)Chiller Cooling Capacity 15 tons(180,000 BTU/hr)Electrical Requirements 208 VAC, 3 Phase, 60Hz, 29.1 kVaDUST COLLECTORModel Torrit, Farr, or equivalentDischarge Port Size 11.8” DiameterPower Requirements 208 VAC, 3 Phase, 60Hz, 10 kVAGAS REGULATOR AND CONNECTION KITLaser Gases One (1) Regulator and One (1) Length of 25ft Hose.Assist Gases Two (2) Regulators and Two (2) Lengths of 25ft Hose.Safety Glasses 1 PairPage